Tripplite.gif (1794 bytes)

digiline4.gif (5068 bytes)

SMART3000RM2U.jpg (24469 bytes)

Tripp-Lite - SmartPro 2U Rack/Tower Extended Run UPS- 3000VA
Qty: Price: $917.56

Smart Pro 3000 Rackmnt 2U UPS; line-inter 9-outlet DB9 USB
MODEL- SMART3000RM2U       VENDOR- TRIPPLITE
                                                                            
FEATURES- SMART3000RM2U-Tripp-Lite - SmartPro 2U Rack/Tower
       SmartPro line interactive 2U expandable rack/tower UPS with 
        integrated switched PDU.
       3000VA line interactive UPS for server, network and 
        telecommunications equipment/2U rackmount form factor/Corrects 
        brownouts and overvoltages from 79 to 147, Sine wave output, 
        Uninterruptible Power Supply (UPS) maintains battery derived AC 
        output during blackouts and severe voltage fluctuations.
       Expandable runtime with optional external battery packs/9 output 
        receptacles/NEMA 5-20P input plug, NEMA L5-30P replacement plug 
        included/Network-grade AC surge and noise suppression/Network 
        management interfaces include 2 USB ports, 2 DB9 serial ports and 
        SNMPWEBCARD slot.
       Supports simultaneous detailed monitoring of equipment load levels, 
        self-test data and mains power conditions via all 5 network 
        interfaces at once. Includes PowerAlert monitoring software and 
        complete cabling/Emergency Power Off (EPO) interface/Integrated 3 
        bank switched PDU/3 stage metered current monitoring and battery 
        charge LEDs/Mains power and voltage regulation LEDs/Audible alarm/ 
        Self-test/4 post rack mounting accessories/2-9USTAND and 2POSTRMKIT 
        accessories available/Field replaceable, hot swappable internal 
        batteries and battery packs/Attractive all-black UPS design.
       Find the TrippLite UPS appropriate for your needs. Try the TrippLite UPS Sizing Guide Today.
 Includes SMART3000RM2U UPS System, PowerAlert Software and cabling,
   Mounting hardware, Warranty information and Instruction manual.
* 3000VA/2250 watt output power capacity compatible with North American 
  120V/60Hz power.
* 2U rack/tower UPS installs in standard 19 inch rack enclosures with an 
  installed depth of only 19 inches.
* Protects sensitive networking equipment from blackouts, voltage 
  fluctuations and transient surges.
* Line interactive Automatic Voltage Regulation (AVR) corrects inputs from 
  79~147VAC back to usable 120V levels without consuming battery power.
* Dual boost AVR circuits boost undervoltages by 14% or 24% depending on 
  the severity and reduces overvoltages by 12%.
* Network interfaces support simultaneous communications via 2 USB, 2 DB9 
  serial and SNMPWEBCARD slot.
* Included PowerAlert UPS monitoring software supports safe unattended 
  shutdown, monitoring and control via local connected servers, plus any 
  number of additional servers over IP.
* Communications ports support on-battery, low-battery, power-restored, AC-
  voltage, DC-voltage, output current monitoring, battery charge current, 
  battery capacity, internal UPS temperature, AC line frequency, timed 
  inverter shutoff, activate self-test and load bank output power control.
* Built in Emergency Power Off (EPO) interface with cable.
* Sine wave output in AC and battery modes.
* Expandable runtime with optional battery packs -- BP48V24-2U (limit 1) 
  and BP48V60RT-3U (multi-pack compatible).
* Half load runtime of 13 minutes with internal batteries, Add 1 BP48V24-2U 
  for 45 minutes or 1 BP48V60RT-3U for 98 minutes (1500VA/1120 watts). 
* Full load runtime of 4 minutes with standard internal batteries, Add 1 
  BP48V24-2U for 20 minutes (3000VA/2250 watts).
* Includes 9 output receptacles arranged in 3 load banks (4 NEMA 5-15R/
  4 NEMA 5-15/20R/1 NEMA L5-20R).
* Ships with NEMA 5-20P input plug, user installable NEMA 5-30P replacement 
  plug included.
* Integrated 3 bank switched PDU enables remote outlet management for load 
  shedding or remote reboot of individual devices.
* 3 stage metered LEDs offer current monitoring and battery charge level.
* Mains power and voltage regulation LEDs offer at-a-glance power status 
  information.
* Front panel switches support self-test and alarm cancel functions.
* Included UPSRMRII adjustable mounting rails support installation in 19 
  inch racks with a front-to-rear depth of 23.5 and 36.5 inches (add a 2nd 
  UPSRMRII accessory to extend the reach to 35.25 to 49.5 inches).
* UPS ships fully assembled in full compliance with DOT regulations, no 
  time consuming connection of internal batteries by user required.
* Supports 2 post rackmount installation with optional 2POSTRMKIT 
  accessory.
* Supports upright tower placement with optional 2-9USTAND accessory.
* UL (USA), cUL (Canada), NOM (Mexico), FCC Class A (Emissions) listed.
* 2 year manufacturers product warranty, $250,000 Ultimate Lifetime 
  Insurance.
   
  -- SPECIFICATIONs -------------------------------------
OUTPUT       - Volt amp capacity  : 3000 VA
               Watt capacity      : 2250 watts 
               Nominal Voltage    : 120V 
               Voltage regulation : LINE MODE- Sine wave line voltage 120V 
                                               (-18%/+8%)
                                    BATT.MODE- Sine wave output 120V +/-5%
               Freq. regulation   : LINE MODE- Passes line frequency of 
                                                60Hz +/-10% 
                                    BATT.MODE- Inverter output regulated to 
                                                 60Hz +/-0.5Hz 
               Outlets            : 9 outlets (4 NEMA 5-15R 
                                               4 NEMA 5-15/20R
                                               1 NEMA L5-20)
               Customized load 
                      management  : 3 individually controllable pairs of 
                                     outlets support automated load 
                                     shedding and remote reboot on demand 
                                     of locked network devices. 
                                     Configurable via PowerAlert software 
                                     to automatically switch off optional 
                                     loads, like monitors, to increase 
                                     available runtime for servers and 
                                     other critical devices.
               Overload protection: Resettable circuit breaker 
INPUT        - Max. amps/watts    : 24A
               Connection type    : NEMA L5-30P input plug (includes user 
                                     installable NEMA 5-20P replacement 
                                     plug).
               Cord length        : 10.0 ft., 10 guage
               Rec. electrical   
                         service  : 30A, 120V
COMMUNICATIONS-  
              Network monitor port: Includes 4 built-in monitoring ports, 
                                     2-USB & 2-DB9. Each supports on 
                                     battery, low battery, power restored, 
                                     AC line voltage, DC battery voltage, 
                                     load percentage, battery charge 
                                     current, battery capacity, internal 
                                     UPS temperature and line frequency 
                                     status messaging. Interface supports 
                                     timed inverter shutoff after 
                                     unattended shutdown, activate self-
                                     test and 10 second reboot of connected 
                                     equipment. Supports reboot of all 
                                     connected devices at once via software 
                                     interface. Compatible with Tripp 
                                     Lite's PowerAlert software. 
              Software and cabling
                          included: Includes PowerAlert UPS monitoring 
                                     software for all common network and 
                                     standalone operating systems. Ships 
                                     with 4 cables, 2-USB to USB & 2-DB9 
                                     to DB9.
              SNMP compatibility : Built-in accessory slot accommodates 
                                    internal SNMPWEBCARD and other network 
                                    accessories.
              WatchDog 
                    compatibility: Yes, compatible with Tripp Lite's 
                                    WatchDog system service software to 
                                    restore operation to locked equipment 
                                    through soft reboot of application/OS 
                                    or hard power off/on reboot of 
                                    connected equipment - ideal for 
                                    unattended kiosk applications.
BATTERY      - Full load runtime :  4 minutes (3000VA), 45 minutes with 
                                      1 BP48V60RT3U.
               Half load runtime : 13 minutes (1500VA), 98 minutes with 
                                      1 BP48V60RT3U.
               Expandable battery
                          runtime: Supports extended runtime with optional 
                                    external battery packs BP48V242U (limit 
                                    1) and BP48V60RT3U (multi-pack 
                                    compatible).
               DC system voltage : 48V DC 
               Typical battery 
                         lifespan: 3-6 years, depending on usage 
               Batt.recharge rate: 2-4 hours to 90% 
               Battery Access    : Battery access door allows hot swap 
                                    battery replacement without powering 
                                    connected equipment off.
SURGE/NOISE SUPPRESSION-
               AC surge suppression: 1800 joules 
               AC suppression
                      response time: Instantaneous 
               EMI/RFI AC noise
                        suppression: Yes 
LINE/BATTERY TRANSFER-
               Time from line power 
                    to battery mode: 2~4 milliseconds 
               Low voltage transfer
                   to battery power: 79V (resets to line power as voltage 
                                      increases to 83V).
               High voltage transfer
                   to battery power: 147V (resets to line power as voltage 
                                     decreases to 144V).
VOLTAGE REGULATION-
               Voltage regulation  : Automatic Voltage Regulation (AVR) 
                                      circuits maintain clean, regulated 
                                      computer-grade 120V nominal output, 
                                      without using battery power, during 
                                      brownouts to 79V and overvoltages to 
                                      147V.
               Overvoltage 
                         correction: Input voltages between 128 and 147VAC 
                                      are reduced by 12%.
               Direct pass through : Input voltages between 105 and 127VAC 
                                      are passed on to connected equipment 
                                      unchanged.
               Brownout correction : Input voltages between 95 and 104VAC 
                                      are boosted by 12%.
               Severe brownout 
                         correction: Input voltages between 79 and 94VAC 
                                      are boosted by 24%.
LEDS ALARMS & SWITCHES-
               Front panel LEDs    : 5 front panel LEDs - Green POWER LED, 
                                      Green VOLTAGE CORRECTION LED, 3 color 
                                      BATTERY CHARGE LED, 3 color OUTPUT 
                                      LOAD LED, red BATTERY WARNING LED.
               Alarms              : 3 function audible alarm indicates 
                                      power failure conditions (4 short 
                                      beeps every 10 seconds), overload 
                                      (continuous short beeps) and low 
                                      battery (continuous tone).
               Switches            : Yes, includes 2 front panel mounted 
                                      push-button switches for system 
                                      enable, self-test and alarm cancel 
                                      functions.
SPECIAL FEATURES-
               EPO port            : Includes RJ11 EPO (emergency power 
                                      off) port and interconnection cable.
               TVSS grounding      : Includes back panel grounding point 
                                      with thumbscrew for data line surge 
                                      suppressors and other network 
                                      accessories requiring a safe 
                                      grounding point.
               Cold Start          : Yes, inverter can be "cold started" to 
                                      enable temporary AC output during a 
                                      power failure.
               Appearance          : Attractive gray rackmount housing,
                                      optional 2U black front bezel 
                                      included to enable black color 
                                      appearance.
               Construction        : Steel 
               Form factors 
                          supported: Ships with all accessories required 
                                      for 2U rackmount installation in a 
                                      4 post rack enclosure, 2 post 
                                      rackmount supported with optional 
                                      2POSTRMKIT, supports tower 
                                      installation with optional 2-9USTAND.
               Cooling method      : Fan 
ENVIRONMENTAL- Operating Temperature: +32 ~ +104 degrees Fahrenheit 
                                      0 ~ +40 degrees Celsius 
               Storage Temperature  : +5 ~ +122 degrees Fahrenheit 
                                      -15 ~ +50 degrees Celsius 
               Relative Humidity    : 0 to 95%, non-condensing 
               Line mode BTU/hr.    : 285.4 BTU max.
APPROVALS    - UL1778 (USA), cUL (Canada), FCC Class A (emissions), NOM 
                (Mexico).
SIZE - 17.5"w x 3.5"h x 19.0"d               WT.- 64 lbs.
We diligently strive to provide as accurate information as possible. However, as manufacturers provide a large proportion of this information, we make no warranty expressed or implied with respect to accuracy of the information, including price, product descriptions or product specifications. Both the product and manufacturer names are used only for the purpose of identification.

digiline4.gif (5068 bytes)

 fax_order_form629.gif (2875 bytes)

digiline4.gif (5068 bytes)

bm_back.gif (3629 bytes)

digiline4.gif (5068 bytes)

Copyright© 2008  JMAC ELECTRONICS